Specifications

dimensions

Dimensions (mm)

Dimensions (inch)

2270*610*60

89.37 * 24.0162 * 2.362

2270*610*75

 89.37 * 24.0162 * 2.953

2270*610*90

89.37 * 24.0162 * 3.543

2270*610*100

89.37 * 24.0162 * 3.937

2270*610*120

89.37 * 24.0162 * 4.724

2270*610*150

89.37 * 24.0162 * 5.906

 2270*610*180

89.37 * 24.0162 * 7.087

2270*610*200

89.37 * 24.0162 * 7.874

weight

KG/panel

KG/m²

lbs/panel

lbs/ft²

 62±5

45±5

137±5

9.19

69±5

50±5

 152±5

10.20

76±5

55±5

168±5

11.27

83±5

60±5

183±5

12.28

90±5

 65±5

198±5

13.28

117±5

85±5

258±5

17.31

138±5

100±5

 304±5

20.40

 152±5

110±5

335±5

22.48

Certified Performance Compressive Load

ASTM E72: Panel consisting of 5mm boards & 140 mm thick honeycomb concrete core w/ expanded polystyrene | Results: Maximum compressive load (lbs) 

SAMPLE 1: 30,343 lbs; SAMPLE 2: 26,971 lbs;  SAMPLE 3: 29,219; Average: 28,844 lbs.

Evaluation: Intertek Report No. 211230011SHF-001

Maximum loads were reached, failure appeared at the end groove of the panel. But there was no significant damage to the panels.

Certified Fire Resistance

ASTM E119: Temperature 1,700 degrees Celsius | Duration: 3 hours
Exposure to high-pressure water immediately following prolonged fire exposure.


Evaluation: Intertek ETL SEMKO


Registered marginal temperature change on opposing surfaces.

Moisture / Mould Resistant

ASTM E96: Standard test methods for water vapor transmission of materials.


Evaluation: Intertek ETL SEMKO
Registered no detectable moisture penetration through composite.

Thermal Non-Conduction

ASTM C177: Evaluates thermal conductivity (insulative properties).


Evaluation: Intertek ETL SEMKO
Registered low thermal conductivity (high insulation values).